Traditerm® Taco Anclaje H1 ECO

Wall anchor plug for insulating panels attachment in the TRADITERM external thermal insulator system. High quality and safety plug.


Download technical data sheet


Additional information

Composition

Polyethylene anchor plug with solid steel nail (anti-cracking).

Features and applications

  • Quick and easy to use. Pre- setting nails.
  • It ensures a high-quality attachment of the panels to the substrate.
  • European Certification wall anchor plug.
  • High performance = Minimal breakage. Telescopic anchor effect.
  • Resistant to open air.
  • Useful for any kind of insulating panel. Attachment of Insulating panels in the TRADITERM external thermal insulator system.
  • Use category according to ETA standard A=Concrete / B=Solid brick / C=Perforated Brick, D =Concrete Light / E = Cellular Concrete.
  • Range of sizes according to the thickness of the sheet.
  • Due to its shape and design, it does not produce any thermal bridges.
  • Short recess depth, minimal drill depth.

Substrates

Suitable for concrete, solid and perforated masonry.

Instructions for use

  • After 24 hours of the attachment to the façade, of the insulating plates with the Traditerm adhesive, make a hole in the substrate using a drill, crossing the insulating plate. The drill bit must have a diameter of 8 mm and the depth of the drill in the substrate must be at least 35 mm adding the thickness of the adhesive and whatever it needs to penetrate in the substrate.
  • Place the Traditerm H1 wall anchor plug in the hole, until it touches the insulating panel. With the help of a mallet, hit the wall plug, so it gets inside until cutting the surface into 1- 2 mm from the insulating panel.
  • Subsequently, the recess produced on the surface of the insulating panel is regularized with TRADITERM mortar.

Cautions and recommendations

  • The dowel must be inserted at least 25 mm inside the substrate without taking into account the thickness of the adhesive.
  • The plug must cut the insulating panel 1-2 mm. If the plug is not correctly introduced in the insulator, it will be seen in the final finish.
  • Make sure the plugs are correctly attached.
  • Depending on the insulating panel thickness, the following H1 ECO anchor plug thicknesses are recommended:

LD = hD + ttol + ttol1 + hef

 

 

 

 

 

 

 

 

 

  • hD : Insulating panel thickness.
  • hef : Deepness of the wall anchor plug ( 25 mm minimum).
  • H1 : Deepness of the drilling.
  • ttol : Traditerm adhesive thickness.
  • ttol1 : Thickness of the existent coating ( Rehabilitation).
  • hk : Thickness of the insulating cover (20 mm) in case of using it.
Thickness of the Traditerm® Panel Insulator mm Anchor plug length (LD) in mm, depending on ttol+ttol1
10 30 50
Substrates A,B,C y D Substrate E Substrates A,B,C y D Substrate E Substrates A,B,C y D Substrate E
40 95* 95 95 - - -
60 95 115 115 135 135 -
80 115 135 135 155 155 175
100 135 155 155 175 175 195
120 155 175 175 195 195 215
140 175 195 195 215 215 235
160 195 215 215 235 235 255
180 215 235 235 255 255 275
200 235 255 255 275 275 295

*If the anchor is recessed at hef 45mm, confirmation by on-site testing is recommended..

 

Packaging

Wall anchor plugs are provided in boxes of 100 units. Keep the wall anchors away from open air and direct sun light.

Technical data

Pre-drilled diameter 8 mm
Washer diameter 60 mm
Minimum anchor depth in the Substrate 25 mm
Standardisation ETA-11/0192
Punctual thermal transmittance 0,001 W/K
Use categories according to ETA standards A=Concrete / B=Solid brick / C=Perforated Brick, D = Light / E = Cellular Concrete
Performance 6 units minimum/m2

Note

The instructions for use are given according to our tests and knowledge and do not imply any commitment by GRUPO PUMA nor free the consumer from the examination and verification of the products for their correct use. Claims must be accompanied by the original packaging to allow a proper traceability.

GRUPO PUMA is not responsible, in any case, for the application of its products or constructive solutions carried out by the application company or other parties involved in the process and / or execution of the work, limiting the responsibility of GRUPO PUMA exclusively to the damages directly attributable to the supplied products, individually or integrated in systems, due to failures in their manufacturing process.

In any case, the drafter of the work project, the technical management or the person responsible for the work, or collaterally the application company or other parties involved in the process and / or execution of the work, must ensure the suitability of the products addressing the characteristics of them, as well as the conditions, support and possible pathologies of the work in question.

The values obtained by GRUPO PUMAS's products or its constructive solutions that, as the case may be, are determined by the EN standards or any other regulation that applies to it in each case refers exclusively to the conditions specifically stipulated in said regulation and that are referred to, among others, to certain characteristics of the support, humidity and temperature conditions, etc. without being them required in the tests obtained under different conditions, all in accordance with the relevant regulation.