Pumafix TQP

Injection resin for anchorage, 2-component and fast curing, resin-based polyester. Styrene-free. Multifunctional, for solid or hollow substrates.


Download technical data sheet


Additional information

Composition

Styrene-free, unsaturated polyester resin.

Features and applications

  • Chemical bonding of horizontal and vertical anchors.
  • Suitable for solid and hollow substrates.
  • Styrene-free; low odour.
  • Easy extrusion and injection.
  • Thixotropic, can be applied either horizontally or vertically.
  • Fast curing.
  • Can be applied with conventional guns.
  • For use on concrete, bricks and concrete masonry units in a wide range of applications: bonding doors, railings, balustrades, Persian blinds, awnings, aerials, signs, cable tray channelling, industrial machinery…

Substrates

  • Substrates must be resistant, stable, sound and clean, free of dust, demolding agents, organic products, etc. It is not necessary for them to be 28 days old.
  • If the condition of the substrate is unknown, it is recommended to carry out extraction tests to test the suitability of the substrate.
  • Once the perforation of the substrate has been made, clean any residue using compressed air or a cylindrical brush.
  • Threaded or round steel rods must be free from any oil or grease.

Instructions for use

INSTALLATION INSTRUCTIONS FOR SOLID BRICKWORK

  • Drill a hole in accordance with the diameter and depth shown on the application table. During the drilling process, the perpendicularity of the hole in the substrate should be checked.  
  • Clean the hole of dust, fragments, oil, water, grease and other contaminants before injecting the mortar (with the manual blower and standard manual brush). 
  • The cleaning of the hole consists of 4 blowing operations, 4 brushing operations followed by a further 4 blowing operations. 
  • Before brushing, the brush must be cleaned and the diameter checked to ensure it is the correct size.  
  • The threaded rod must be free from any dust, grease, oil and other impurities. 
  • Unscrew the top of the cartridge, engage the mixing nozzle to the cartridge and position in the gun. 
  • At the start of using a new cartridge, eject some product until a uniform colour of the mortar appears.
  • Fill the drilled hole uniformly from the bottom up to avoid air pockets, moving the nozzle slowly outwards. 
  • Fill 2/3 of the depth of the drilled hole with mortar.
  • Insert the threaded rod slowly and with a slight rotating movement, remove the excess mortar injected from around the threaded rod. 
  • Wait the necessary curing time in accordance with the datasheet.
  • Do not move or load the anchor until the curing process has finished.

INSTALLATION INSTRUCTIONS FOR HOLLOW/PERFORATED BRICKWORK 

  • Drill a hole in accordance with the diameter and depth shown on the application table. During the drilling process, the perpendicularity of the hole in the substrate should be checked.
  • Clean the hole of dust, fragments, oil, water, grease and other contaminants before injecting the mortar (with the manual blower and standard manual brush). 
  • The cleaning of the hole consists of 4 blowing operations, 2 brushing operations followed by a further 4 blowing operations.
  • Before brushing, the brush must be cleaned and the diameter checked to ensure it is the correct size. 
  • The threaded rod must be free from any dust, grease, oil and other impurities.  
  • Select the correct size of sieve.
  • Unscrew the top of the cartridge, engage the mixing nozzle to the cartridge and position in the gun. 
  • At the start of using a new cartridge, eject some product until a uniform colour of the mortar appears.
  • Remove the top of the plastic sieve.
  • Introduce the plastic sieve in the hole.
  • Fill the sieve uniformly from the bottom up, moving the mixing nozzle slowly towards the outside: move the mixing nozzle 10 mm  towards the outside each time you pull the trigger. 
  • Completely fill the sieve.
  • Place the top on the filled plastic sieve. 
  • Insert the threaded rod slowly and with a slight rotating movement, remove the excess mortar injected from around the threaded rod. 
  • Wait the necessary curing time in accordance with the datasheet. 
  • Do not move or load the anchor until the curing process has finished.

 

Number of Anchors per drilled hole diameter

Anchor INSTALLATION IN HOLLOW SUBSTRATES
Rod Sieve 16/85 Sieve 16/130
  280 ml 280 ml
M8 11 7
M10 11 7
M12 11 7
M16 - -
M20 - -

Anchor

INSTALLATION OF CONCRETE RODS
Rod  
  280 ml
M8 65/75
M10 37/40
M12 22/25
M16 11/13
M20 5/6

See application tables for hole depth and diameter values

APPLICATION TABLE FOR RODS IN HOLLOW SUBSTRATES

Anchor Installation Permissible loads
Nozzle

Rod class 5.8

Drill piece diameter d0 Drill depth Hole depthhef Torque Tinst Hollow bricks fcm: 4,50 MPa Concrete masonry units fcm: 6,00 MPa
   


[mm]


[mm]


[mm]


[Nm]

Traction
[kN]

Shears
[kN]

Traction
[kN]

Shears
[kN]

16/85 M8 17 90 85 4 0,40 1,10 - -
16/85 M10 17 90 85 4 0,40 1,10 - -
16/85 M12 17 90 85 4 0,40 1,10 - -
                   
16/130 M8 17 135 130 4 - - 0,70 1,50
16/130 M10 17 135 130 4 - - 0,70 1,50
16/130 M12 17 135 130 4 - - 0,70 1,50

APPLICATION TABLE POR CONCRETE RODS

Anchor Installation Resistance Permissible load
Rod class 5.8 Drill piece diameter d0 Hole depth h ef Standard distance edges CCr Standard distance anchors SCr Torque Tinst Characteristic resistance NRk Concrete C20/25 Concrete C20/25
 
[mm]

[mm]

[mm]

[mm]

[N.m]
Traction
[kN]
Traction
[kN]
Shears
[kN]
M8 10 80 80 160 10 14,7 4,9 5,8
M10 12 90 90 180 20 20,5 6,8 9,2
M12 14 110 110 220 40 34,6 11,5 13,4
M16 18 125 125 250 60 47,9 16,0 24,9
M20 24 170 170 340 100 81,4 27,1 39,2

Safety factor of 3.0 load stress

Cautions and recommendations

  • Do not apply under 5ºC nor above 30ºC. Higher temperatures will considerably reduce the life of the mixture.
  • Using on site and adjustments to the product are only possible before the hardening of PUMAFIX TQP.
  • The anchor point must be positioned within the open time.
  • During the hardening of the resin the anchor must not be moved or loaded (wait for the necessary time).
  • Store between 5ºC and not above 25ºC 
  • Consult the product label. For more information see the safety datasheet. Please respect regulations, hygiene and waste disposal in the workplace.

Packaging

80 ml 2-component cartridges.

Shelf life: 18 month in sealed original packaging, sheltered from weather conditions and humidity and stored between 5ºC and not above 25ºC.

Technical data

(Statistical data obtained under standard conditions)

Density 1,80 Kg/dm³
Colour Light Grey (Comp. A: beige; Comp. B: black)
Resistance to compression  (ASTM  D695) 63  N/mm²
Compression module  (ASTM  D695) 6300  N/mm²
Open time and speed of curing
 Application temperature Open time Curing time
5º C 15 min. 120 min.
10º C 12 min. 90 min.
20º C 6 min. 45 min.
30º C 3 min. 20 min.

 

Note

The instructions for use are given according to our tests and knowledge and do not imply any commitment by GRUPO PUMA nor free the consumer from the examination and verification of the products for their correct use. Claims must be accompanied by the original packaging to allow a proper traceability.

GRUPO PUMA is not responsible, in any case, for the application of its products or constructive solutions carried out by the application company or other parties involved in the process and / or execution of the work, limiting the responsibility of GRUPO PUMA exclusively to the damages directly attributable to the supplied products, individually or integrated in systems, due to failures in their manufacturing process.

In any case, the drafter of the work project, the technical management or the person responsible for the work, or collaterally the application company or other parties involved in the process and / or execution of the work, must ensure the suitability of the products addressing the characteristics of them, as well as the conditions, support and possible pathologies of the work in question.

The values obtained by GRUPO PUMAS's products or its constructive solutions that, as the case may be, are determined by the EN standards or any other regulation that applies to it in each case refers exclusively to the conditions specifically stipulated in said regulation and that are referred to, among others, to certain characteristics of the support, humidity and temperature conditions, etc. without being them required in the tests obtained under different conditions, all in accordance with the relevant regulation.