Pegoland® Flex Record C2 TE S2

Two component high performance cementitious adhesive for very demanding applications.
Specially suitable for heavy tiles on walls and floors of large application areas.
Suitable for bonding all types of ceramic tiles. Indoor and outdoor application.

12004 - C2 TE S2 Casita_MuroIntExt_SueloIntExt

Download technical data sheet


Additional information

Composition

Two component product based on high resistance white cement, selected aggregates, special additives and dispersion resins.

Features and applications

  • To be applied indoors and outdoors. Façades.
  • Suitable for all types of ceramic tiles and natural stone (marble, limestone, granite). Highly recommended for large and very large format tiles.
  • Non slip. Excellent initial adherence.
  • Long open time. Allows rectification.
  • Flexible.
  • To tile large areas with intense traffic and floors with underfloor heating.

Substrates

  • Conventional cement-based substrates.
  • Indoor and outdoor flooring and indoor ceramic cladding up to 3 meters high
  • Substrates must be resistant, stable, sound and clean, free of dust, demolding agents, organic products, etc.
  • All substrates must have the appropriate flatness. Otherwise, screed up to 5 mm per coat with the same product 48 hours before bonding. For greater thickness, use traditional dry mortars or levelling paste.
  • In case of hot or windy weather conditions or when applying over absorbent substrates, it is advisable to wet the substrate and wait till the thin layer of water disappears.
  • Do not apply on clay or on paint.
  • On outdoor flooring, substrates must have a gradient equal or superior to 1%.

Instructions for use

  • Mix the powder and the liquid resin contained in the package. Use a mixer until a homogenous paste is obtained.
  • Let the mixture stand for 5 minutes and remix.
  • Spread the mixed product on the substrate with a trowel to a maximum surface area of 2m2.
  • Spread with a notched trowel to adjust thickness (see chart).
  • Use double bonding for large format tiles.
  • Lay the tiles, press and make small rotation movements to ensure that the glue gets in total contact with both surfaces.
  • Observe construction joints (expansion, contraction, fraction, perimeter corner joints) and the joints between the cement slabs (minimum 2mm).
  • Joints should be grouted 24 hours after if on vertical surfaces, and 48 hours after if on floorings. Use the appropriate mortar from the MORCEMCOLOR range depending on the type of joint.

NOTE: For better results lay tiles as soon as possible after spreading.

Notched-trowel panel

Maximum weight on vertical surfaces: 60 kg/m2
TILE FORMAT NOTCHED FORMAT BONDING
< 100 cm2 U4 (4 x 4 x 4) Simple
< 450 cm2 U6 (6 x 6 x 6) Simple
< 900 cm2 U6 (6 x 6 x 6) / U9 (9 x 9 x 9) ó n10 Double-Simple
> 900 cm2 U9 (9 x 9 x 9) ó n10 Double

Cautions and recommendations

  • Do not apply below 5ºC nor above 30ºC.
  • Do not apply when there is a risk of frost, rain, strong wind or direct sunlight.
  • Under extreme weather conditions (gusty winds or high temperatures) drying may occur faster.
  • On floor areas larger than 30 m2, leave partition joints to be filled with a flexible material.
  • On interior floorings larger than 15 m2, it is advisable to keep a free perimeter expansion joint between the floor and the wall or pillar, hidden by a baseboard.
  • On floorings with underfloor heating, apply when substrate is at room temperature (between 5ºC and 30ºC).
  • Check that the gypsum board is firmly fixed before applying on it.
  • For gypsum based substrates, use PEGOLAND - GYPSUM, avoiding laked or poor plaster.
  • On façades and exterior facings, the material must be secured with mechanical systems.

Packaging

Kit containing a 20Kg paper bag with the powdered product and a 5.2 Kg plastic bucket with the resin.
Shelf life: 1 year in sealed original packaging, sheltered from weather conditions and humidity.

Technical data

(Statistical data obtained under standard conditions)
Aspect WHITE powder
Apparent density of powder 1,6 ± 0,2 g/cm3
Open time Approx. 20 min.
Adjustment time Approx. 30 min. (depending on weather conditions)
Paste shelf life Approx. 2 hours (depending on weather conditions)
Initial tensile adhesion strenght > 2,0 N/mm2
Tensile adhesion strenght after water inmersion > 1,0 N/mm2
Tensile adhesion strenght after heat ageing > 1,5 N/mm2
Tensile adhesion strenght after freeze-thaw cycles > 1,0 N/mm2
UNE-EN 12004 Classification C2 TE
UNE-EN 12002 Classification S2
Approximate yield 5 Kg/m2

Note

The instructions for use are given according to our tests and knowledge and do not imply any commitment by GRUPO PUMA nor free the consumer from the examination and verification of the products for their correct use. Claims must be accompanied by the original packaging to allow a proper traceability.

GRUPO PUMA is not responsible, in any case, for the application of its products or constructive solutions carried out by the application company or other parties involved in the process and / or execution of the work, limiting the responsibility of GRUPO PUMA exclusively to the damages directly attributable to the supplied products, individually or integrated in systems, due to failures in their manufacturing process.

In any case, the drafter of the work project, the technical management or the person responsible for the work, or collaterally the application company or other parties involved in the process and / or execution of the work, must ensure the suitability of the products addressing the characteristics of them, as well as the conditions, support and possible pathologies of the work in question.

The values obtained by GRUPO PUMAS's products or its constructive solutions that, as the case may be, are determined by the EN standards or any other regulation that applies to it in each case refers exclusively to the conditions specifically stipulated in said regulation and that are referred to, among others, to certain characteristics of the support, humidity and temperature conditions, etc. without being them required in the tests obtained under different conditions, all in accordance with the relevant regulation.